听力与言语-语言病理学

行为科学

医学伦理学

你正在浏览MAGNETIC RESONANCE IN MEDICINE期刊下所有文献
  • Machine learning RF shimming: Prediction by iteratively projected ridge regression.

    abstract:PURPOSE:To obviate online slice-by-slice RF shim optimization and reduce B1+ mapping requirements for patient-specific RF shimming in high-field magnetic resonance imaging. THEORY AND METHODS:RF Shim Prediction by Iteratively Projected Ridge Regression (PIPRR) predicts patient-specific, SAR-efficient RF shims with a m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27192

    authors: Ianni JD,Cao Z,Grissom WA

    更新日期:2018-11-01 00:00:00

  • Pulmonary artery imaging under free-breathing using golden-angle radial bSSFP MRI: a proof of concept.

    abstract:PURPOSE:To evaluate the feasibility of an improved motion and flow robust methodology for imaging the pulmonary vasculature using non-contrast-enhanced, free-breathing, golden-angle radial MRI. METHODS:Healthy volunteers (n = 10, age 46 ± 11 years, 50% female) and patients (n = 2, ages 27 and 84, both female) were ima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27177

    authors: Fyrdahl A,Vargas Paris R,Nyrén S,Holst K,Ugander M,Lindholm P,Sigfridsson A

    更新日期:2018-11-01 00:00:00

  • An analytic expression for the ultimate intrinsic SNR in a uniform sphere.

    abstract:PURPOSE:The ultimate intrinsic signal-to-noise ratio (UISNR) is normally calculated using electrodynamic simulations with a complete basis of modes. Here, we provide an exact solution for the UISNR at the center of a dielectric sphere and assess how accurately this solution approximates UISNR away from the center. MET...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27207

    authors: Lee HH,Sodickson DK,Lattanzi R

    更新日期:2018-11-01 00:00:00

  • Dual-polarity slice-GRAPPA for concurrent ghost correction and slice separation in simultaneous multi-slice EPI.

    abstract:PURPOSE:A ghost correction strategy for Simultaneous Multi-Slice (SMS) EPI methods that provides improved ghosting artifact reduction compared to conventional methods is presented. Conventional Nyquist ghost correction methods for SMS-EPI rely on navigator data that contain phase errors from all slices in the simultane...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27113

    authors: Hoge WS,Setsompop K,Polimeni JR

    更新日期:2018-10-01 00:00:00

  • CEST, ASL, and magnetization transfer contrast: How similar pulse sequences detect different phenomena.

    abstract::Chemical exchange saturation transfer (CEST), arterial spin labeling (ASL), and magnetization transfer contrast (MTC) methods generate different contrasts for MRI. However, they share many similarities in terms of pulse sequences and mechanistic principles. They all use RF pulse preparation schemes to label the longit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.27341

    authors: Knutsson L,Xu J,Ahlgren A,van Zijl PCM

    更新日期:2018-10-01 00:00:00

  • A multicontrast imaging method using steady-state free precession with alternating RF flip angles.

    abstract:PURPOSE:To obtain multicontrast images including fat-suppressed contrast image, a novel multicontrast imaging method using an SSFP sequence with alternating RF flip angles is proposed. METHODS:The proposed method uses the balanced SSFP sequence with 2 flip angles. In general, the conventional balanced SSFP sequence ha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27342

    authors: Kim J,Seo H,So S,Park H

    更新日期:2018-10-01 00:00:00

  • Fast nonlinear susceptibility inversion with variational regularization.

    abstract:PURPOSE:Quantitative susceptibility mapping can be performed through the minimization of a function consisting of data fidelity and regularization terms. For data consistency, a Gaussian-phase noise distribution is often assumed, which breaks down when the signal-to-noise ratio is low. A previously proposed alternative...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27073

    authors: Milovic C,Bilgic B,Zhao B,Acosta-Cabronero J,Tejos C

    更新日期:2018-08-01 00:00:00

  • Cardiac gating using scattering of an 8-channel parallel transmit coil at 7T.

    abstract:PURPOSE:To establish a cardiac signal from scattering matrix or scattering coefficient measurements made on a 7T 8-channel parallel transmit (pTx) system, and to evaluate its use for cardiac gating. METHODS:Measurements of the scattering matrix and scattering coefficients were acquired using a monitoring pulse sequenc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27038

    authors: Jaeschke SHF,Robson MD,Hess AT

    更新日期:2018-08-01 00:00:00

  • High resolution hyperpolarized 13 C MRSI using SPICE at 9.4T.

    abstract:PURPOSE:To test the feasibility of using the SPICE (SPectroscopic Imaging by exploiting spatiospectral CorrElation) technique, which uses the partial separability of spectroscopic data, for high resolution hyperpolarized (HP) 13 C spectroscopic imaging. METHODS:Numerical simulations were performed to investigate the i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27061

    authors: Lee H,Song JE,Shin J,Joe E,Joo CG,Choi YS,Song HT,Kim DH

    更新日期:2018-08-01 00:00:00

  • Diffusion sensitivity of 3D-GRASE in arterial spin labeling perfusion.

    abstract:PURPOSE:To evaluate the role of true diffusion and flow-related pseudodiffusion in cerebral blood flow (CBF) quantification using arterial spin labeling (ASL) with single-shot or segmented 3D gradient and spin echo (GRASE) readouts. THEORY:The extended phase graph (EPG) algorithm, originally designed to model the effe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27058

    authors: He X,Wengler K,Schweitzer ME

    更新日期:2018-08-01 00:00:00

  • Relationships between tissue microstructure and the diffusion tensor in simulated skeletal muscle.

    abstract:PURPOSE:To establish a series of relationships defining how muscle microstructure and diffusion tensor imaging (DTI) are related. METHODS:The relationship among key microstructural features of skeletal muscle (fiber size, fibrosis, edema, and permeability) and the diffusion tensor were systematically simulated over ph...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26993

    authors: Berry DB,Regner B,Galinsky V,Ward SR,Frank LR

    更新日期:2018-07-01 00:00:00

  • A z-gradient array for simultaneous multi-slice excitation with a single-band RF pulse.

    abstract:PURPOSE:Multi-slice radiofrequency (RF) pulses have higher specific absorption rates, more peak RF power, and longer pulse durations than single-slice RF pulses. Gradient field design techniques using a z-gradient array are investigated for exciting multiple slices with a single-band RF pulse. THEORY AND METHODS:Two d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27031

    authors: Ertan K,Taraghinia S,Sadeghi A,Atalar E

    更新日期:2018-07-01 00:00:00

  • The effects of intravoxel contrast agent diffusion on the analysis of DCE-MRI data in realistic tissue domains.

    abstract:PURPOSE:Quantitative evaluation of dynamic contrast enhanced MRI (DCE-MRI) allows for estimating perfusion, vessel permeability, and tissue volume fractions by fitting signal intensity curves to pharmacokinetic models. These compart mental models assume rapid equilibration of contrast agent within each voxel. However, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26995

    authors: Woodall RT,Barnes SL,Hormuth DA 2nd,Sorace AG,Quarles CC,Yankeelov TE

    更新日期:2018-07-01 00:00:00

  • MRI monitoring of focused ultrasound sonications near metallic hardware.

    abstract:PURPOSE:To explore the temperature-induced signal change in two-dimensional multi-spectral imaging (2DMSI) for fast thermometry near metallic hardware to enable MR-guided focused ultrasound surgery (MRgFUS) in patients with implanted metallic hardware. METHOD:2DMSI was optimized for temperature sensitivity and applied...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27034

    authors: Weber H,Ghanouni P,Pascal-Tenorio A,Pauly KB,Hargreaves BA

    更新日期:2018-07-01 00:00:00

  • Optimization and validation of accelerated golden-angle radial sparse MRI reconstruction with self-calibrating GRAPPA operator gridding.

    abstract:PURPOSE:Golden-angle radial sparse parallel (GRASP) MRI reconstruction requires gridding and regridding to transform data between radial and Cartesian k-space. These operations are repeatedly performed in each iteration, which makes the reconstruction computationally demanding. This work aimed to accelerate GRASP recon...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27030

    authors: Benkert T,Tian Y,Huang C,DiBella EVR,Chandarana H,Feng L

    更新日期:2018-07-01 00:00:00

  • Template-based field map prediction for rapid whole brain B0 shimming.

    abstract:PURPOSE:In typical MRI protocols, time is spent acquiring a field map to calculate the shim settings for best image quality. We propose a fast template-based field map prediction method that yields near-optimal shims without measuring the field. METHODS:The template-based prediction method uses prior knowledge of the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27020

    authors: Shi Y,Vannesjo SJ,Miller KL,Clare S

    更新日期:2018-07-01 00:00:00

  • RACER-GRASP: Respiratory-weighted, aortic contrast enhancement-guided and coil-unstreaking golden-angle radial sparse MRI.

    abstract:PURPOSE:To develop and evaluate a novel dynamic contrast-enhanced imaging technique called RACER-GRASP (Respiratory-weighted, Aortic Contrast Enhancement-guided and coil-unstReaking Golden-angle RAdial Sparse Parallel) MRI that extends GRASP to include automatic contrast bolus timing, respiratory motion compensation, a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27002

    authors: Feng L,Huang C,Shanbhogue K,Sodickson DK,Chandarana H,Otazo R

    更新日期:2018-07-01 00:00:00

  • Design of universal parallel-transmit refocusing kT -point pulses and application to 3D T2 -weighted imaging at 7T.

    abstract:PURPOSE:T2 -weighted sequences are particularly sensitive to the radiofrequency (RF) field inhomogeneity problem at ultra-high-field because of the errors accumulated by the imperfections of the train of refocusing pulses. As parallel transmission (pTx) has proved particularly useful to counteract RF heterogeneities, u...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27001

    authors: Gras V,Mauconduit F,Vignaud A,Amadon A,Le Bihan D,Stöcker T,Boulant N

    更新日期:2018-07-01 00:00:00

  • Apparent diffusion coefficients of the five major metabolites measured in the human brain in vivo at 3T.

    abstract:PURPOSE:To measure the apparent diffusion coefficients (ADC) of five main metabolites in the human brain at 3T with PRESS and STEAM, avoiding measurement biases because of cross-terms. Cross-terms arise from interactions between slice-selection and spoiler gradients in the localized spectroscopy sequence and the diffus...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26969

    authors: Deelchand DK,Auerbach EJ,Marjańska M

    更新日期:2018-06-01 00:00:00

  • Reconstruction by calibration over tensors for multi-coil multi-acquisition balanced SSFP imaging.

    abstract:PURPOSE:To develop a rapid imaging framework for balanced steady-state free precession (bSSFP) that jointly reconstructs undersampled data (by a factor of R) across multiple coils (D) and multiple acquisitions (N). To devise a multi-acquisition coil compression technique for improved computational efficiency. METHODS:...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26902

    authors: Biyik E,Ilicak E,Çukur T

    更新日期:2018-05-01 00:00:00

  • Application of phase rotation to STRESS localization scheme at 3 T.

    abstract:PURPOSE:Application of phase rotation to the STRESS (=STEAM+PRESS) localization scheme, to shorten echo time, minimize J-coupling dephasing and estimate B1+ inhomogeneity. STRESS (=STEAM + PRESS) simultaneously refocuses and acquires the double spin echo (SE123 ) and stimulated echo (STE- ) pathways, combining PRESS-li...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26911

    authors: Volovyk O,Tal A

    更新日期:2018-05-01 00:00:00

  • Isotropic 3D cardiac cine MRI allows efficient sparse segmentation strategies based on 3D surface reconstruction.

    abstract:PURPOSE:Segmentation of cardiac cine MRI data is routinely used for the volumetric analysis of cardiac function. Conventionally, 2D contours are drawn on short-axis (SAX) image stacks with relatively thick slices (typically 8 mm). Here, an acquisition/reconstruction strategy is used for obtaining isotropic 3D cine data...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26923

    authors: Odille F,Bustin A,Liu S,Chen B,Vuissoz PA,Felblinger J,Bonnemains L

    更新日期:2018-05-01 00:00:00

  • Accuracy, repeatability, and interplatform reproducibility of T1 quantification methods used for DCE-MRI: Results from a multicenter phantom study.

    abstract:PURPOSE:To determine the in vitro accuracy, test-retest repeatability, and interplatform reproducibility of T1 quantification protocols used for dynamic contrast-enhanced MRI at 1.5 and 3 T. METHODS:A T1 phantom with 14 samples was imaged at eight centers with a common inversion-recovery spin-echo (IR-SE) protocol and...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26903

    authors: Bane O,Hectors SJ,Wagner M,Arlinghaus LL,Aryal MP,Cao Y,Chenevert TL,Fennessy F,Huang W,Hylton NM,Kalpathy-Cramer J,Keenan KE,Malyarenko DI,Mulkern RV,Newitt DC,Russek SE,Stupic KF,Tudorica A,Wilmes LJ,Yankeelov TE

    更新日期:2018-05-01 00:00:00

  • Macromolecule mapping of the brain using ultrashort-TE acquisition and reference-based metabolite removal.

    abstract:PURPOSE:To develop a practical method for mapping macromolecule distribution in the brain using ultrashort-TE MRSI data. METHODS:An FID-based chemical shift imaging acquisition without metabolite-nulling pulses was used to acquire ultrashort-TE MRSI data that capture the macromolecule signals with high signal-to-noise...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26896

    authors: Lam F,Li Y,Clifford B,Liang ZP

    更新日期:2018-05-01 00:00:00

  • Hybrid ultrasound-MR guided HIFU treatment method with 3D motion compensation.

    abstract:PURPOSE:Treatments using high-intensity focused ultrasound (HIFU) in the abdominal region remain challenging as a result of respiratory organ motion. A novel method is described here to achieve 3D motion-compensated ultrasound (US) MR-guided HIFU therapy using simultaneous ultrasound and MRI. METHODS:A truly hybrid US...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26897

    authors: Celicanin Z,Manasseh G,Petrusca L,Scheffler K,Auboiroux V,Crowe LA,Hyacinthe JN,Natsuaki Y,Santini F,Becker CD,Terraz S,Bieri O,Salomir R

    更新日期:2018-05-01 00:00:00

  • Effects of imaging gradients in sequences with varying longitudinal storage time-Case of diffusion exchange imaging.

    abstract:PURPOSE:To illustrate the potential bias caused by imaging gradients in correlation MRI sequences using longitudinal magnetization storage (LS) and examine the case of filter exchange imaging (FEXI) yielding maps of the apparent exchange rate (AXR). METHODS:The effects of imaging gradients in FEXI were observed on yea...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26856

    authors: Lasič S,Lundell H,Topgaard D,Dyrby TB

    更新日期:2018-04-01 00:00:00

  • A double echo ultra short echo time (UTE) acquisition for respiratory motion-suppressed high resolution imaging of the lung.

    abstract:PURPOSE:Magnetic resonance imaging is a promising alternative to computed tomography for lung imaging. However, organ motion and poor signal-to-noise ratio, arising from short T2*, impair image quality. To alleviate these issues, a new retrospective gating method was implemented and tested with an ultra-short echo time...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26891

    authors: Delacoste J,Chaptinel J,Beigelman-Aubry C,Piccini D,Sauty A,Stuber M

    更新日期:2018-04-01 00:00:00

  • In vivo whole-blood T2 versus HbO2 calibration by modulating blood oxygenation level in the femoral vein through intermittent cuff occlusion.

    abstract:PURPOSE:To investigate the feasibility of estimating calibration constants (K and T2o ) in vivo for converting whole-blood T2 to blood hemoglobin oxygen saturation (HbO2 ) according to the Luz-Meiboom model, 1/T2=1/T2o+K(1-HbO2)2, where K and T2o are relaxivity and transverse relaxation time of fully saturated blood, r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26885

    authors: Langham MC,Rodríguez-Soto AE,Schwartz N,Wehrli FW

    更新日期:2018-04-01 00:00:00

  • Magnetization-prepared shells trajectory with automated gradient waveform design.

    abstract:PURPOSE:To develop a fully automated trajectory and gradient waveform design for the non-Cartesian shells acquisition, and to develop a magnetization-prepared (MP) shells acquisition to achieve an efficient three-dimensional acquisition with improved gray-to-white brain matter contrast. METHODS:After reviewing the she...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26863

    authors: Shu Y,Tao S,Trzasko JD,Huston J 3rd,Weavers PT,Bernstein MA

    更新日期:2018-04-01 00:00:00

  • MRI assessment of coronary microvascular endothelial nitric oxide synthase function using myocardial T1 mapping.

    abstract:PURPOSE:Endothelial nitric oxide synthase (eNOS) plays a central role in regulating vascular tone, blood flow, and microvascular permeability. Endothelial dysfunction, including eNOS dysfunction, is an early biomarker of vascular disease. This study aimed to show that myocardial T1 mapping during nitric oxide synthase ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26870

    authors: Cui SX,Epstein FH

    更新日期:2018-04-01 00:00:00

  • Direct comparison of in vivo versus postmortem second-order motion-compensated cardiac diffusion tensor imaging.

    abstract:PURPOSE:To directly compare in vivo versus postmortem second-order motion-compensated spin-echo diffusion tensor imaging of the porcine heart. METHODS:Second-order motion-compensated spin-echo cardiac diffusion tensor imaging was performed during systolic contraction in vivo and repeated upon cardiac arrest by bariumc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26871

    authors: Stoeck CT,von Deuster C,Fleischmann T,Lipiski M,Cesarovic N,Kozerke S

    更新日期:2018-04-01 00:00:00

  • Whole-brain arteriography and venography: Using improved velocity-selective saturation pulse trains.

    abstract:PURPOSE:To develop velocity-selective (VS) MR angiography (MRA) protocols for arteriography and venography with whole-brain coverage. METHODS:Tissue suppression using velocity-selective saturation (VSS) pulse trains is sensitive to radiofrequency field (B1 +) inhomogeneity. To reduce its sensitivity, we replaced the l...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26864

    authors: Li W,Xu F,Schär M,Liu J,Shin T,Zhao Y,van Zijl PCM,Wasserman BA,Qiao Y,Qin Q

    更新日期:2018-04-01 00:00:00

  • B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils.

    abstract:PURPOSE:Imaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time-varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26790

    authors: Weavers PT,Tao S,Trzasko JD,Frigo LM,Shu Y,Frick MA,Lee SK,Foo TK,Bernstein MA

    更新日期:2018-03-01 00:00:00

  • Transverse relaxation time constants of the five major metabolites in human brain measured in vivo using LASER and PRESS at 3 T.

    abstract:PURPOSE:The goal of this study was to measure and compare the apparent transverse relaxation time constants (T2 ) of five intracellular metabolites using localization by adiabatic selective refocusing (LASER) and point-resolved spectroscopy (PRESS) sequences in the human brain at 3 T. METHODS:Five healthy subjects wer...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26826

    authors: Deelchand DK,Auerbach EJ,Kobayashi N,Marjańska M

    更新日期:2018-03-01 00:00:00

  • High-resolution 31 P echo-planar spectroscopic imaging in vivo at 7T.

    abstract:PURPOSE:Conventional 31 P chemical shift imaging is time-consuming and yields only limited spatial resolution. The purpose of this study was to demonstrate feasibility of 31 P echo-planar spectroscopic imaging (EPSI) in vivo at 7T. METHODS:A 3D 31 P EPSI sequence with trapezoidal-shaped gradient pulses was implemented...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26785

    authors: Korzowski A,Bachert P

    更新日期:2018-03-01 00:00:00

  • Characterization of pseudo-continuous arterial spin labeling: Simulations and experimental validation.

    abstract:PURPOSE:To characterize pseudo-continuous arterial spin labeling (pCASL) through simulations of spin inversion and to discuss suitable parameter settings for measuring cerebral perfusion. METHODS:Simulations of arterial spin inversion in pCASL were performed based on the Bloch equation. Both the labeling and the contr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26805

    authors: Lorenz K,Mildner T,Schlumm T,Möller HE

    更新日期:2018-03-01 00:00:00

  • Design of spectral-spatial phase prewinding pulses and their use in small-tip fast recovery steady-state imaging.

    abstract:PURPOSE:Spectrally selective "prewinding" radiofrequency pulses can counteract B0 inhomogeneity in steady-state sequences, but can only prephase a limited range of off-resonance. We propose spectral-spatial small-tip angle prewinding pulses that increase the off-resonance bandwidth that can be successfully prephased by...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26794

    authors: Williams SN,Nielsen JF,Fessler JA,Noll DC

    更新日期:2018-03-01 00:00:00

  • Metabolic assessment of a migraine model using relaxation-enhanced 1 H spectroscopy at ultrahigh field.

    abstract:PURPOSE:This study evaluates biochemical imbalances in a rat model that reflects dysfunctional pathways in migraine. The high sensitivity and spectral dispersion available to 1 H MRS at 21.1 T expands metabolic profiling in this migraine model to include lactate (Lac), taurine (Tau), aspartate, and Gly-a mixture of gly...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26811

    authors: Abad N,Rosenberg JT,Roussel T,Grice DC,Harrington MG,Grant SC

    更新日期:2018-03-01 00:00:00

  • Self-calibrated correlation imaging with k-space variant correlation functions.

    abstract:PURPOSE:Correlation imaging is a previously developed high-speed MRI framework that converts parallel imaging reconstruction into the estimate of correlation functions. The presented work aims to demonstrate this framework can provide a speed gain over parallel imaging by estimating k-space variant correlation function...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26818

    authors: Li Y,Edalati M,Du X,Wang H,Cao JJ

    更新日期:2018-03-01 00:00:00

  • Accelerated three-dimensional multispectral MRI with robust principal component analysis for separation of on- and off-resonance signals.

    abstract:PURPOSE:To enable highly accelerated distortion-free MRI near metal by separating on- and off-resonance to exploit the redundancy of slice-phase encoding for the dominant on-resonance component. METHODS:Multispectral MRI techniques resolve off-resonance distortions by a combination of limited excitation bins and addit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26819

    authors: Levine E,Stevens K,Beaulieu C,Hargreaves B

    更新日期:2018-03-01 00:00:00

1170 条记录 4/30 页 « 12345678...2930 »